0818600 0818700 0818800 micro pressure controller uses a diaphragm sensor, which can be used for neutral oil, gas medium and water. The setting value of the controller is adjustable, the adjustment range is 0.2-25kPa, and the working pressure range is 0-0.16MPa.
◇ Main technical performance:
Working viscosity: <1 × 10-3m2 / S
Life: 105 cycles (AC220V 6A resistive)
Rated load: Vmax = 380V AC Imax = 6A (resistive)
Max Pmax = 600V A
Enclosure protection level: 1P54
Environmental temperature: -10 ~ + 55 ℃
Medium temperature: stable working temperature 0 ~ 90 ℃
Anti-vibration performance: 10m / s2.
Repeatability error: ≤1.5%
◇ Main technical performance:
Working viscosity: <1 × 10-3m2 / S
Life: 105 cycles (AC220V 6A resistive)
Rated load: Vmax = 380V AC Imax = 6A (resistive)
Max Pmax = 600V A
Enclosure protection level: 1P54
Environmental temperature: -10 ~ + 55 ℃
Medium temperature: stable working temperature 0 ~ 90 ℃
Anti-vibration performance: 10m / s2.
Repeatability error: ≤1.5%