Description
LKB-01 target flow controller
The LKB-01 target flow controller uses a target sensor. Can be used in water cooling systems or other fluid circuits. The setting value of the controller is adjustable.
◇ Main technical performance:
Ambient temperature: 5 ~ 40 ℃
Installation position: The arrow on the shell is consistent with the direction of the water flow, and a 10D (pipe diameter) guide straight pipe is required in front of the controller.
Installation pipeline: 1-6 "
Pressure resistance: 1.6MPa
Contact capacity: AC 250V 3A (resistive)
1 changeover contact (with normally open and normally closed)
Medium temperature range: 5 ~ 80 ℃
◇ Regulations:
Pipeline and target matching |
Flow adjustment range |
Switch difference |
Repeatability error |
|
Pipe diameter |
Target |
|||
1" |
1# |
20……48 |
8 |
1.1 |
1 1/4" |
1# |
34……100 |
10 |
2.6 |
1 1/2" |
1# |
65……160 |
14 |
3.8 |
2" |
1# |
120……280 |
26 |
6.4 |
* 2 1/2" |
1# |
210……550 |
18 |
|
* 3" |
1# |
380……750 |
20 |
|
2" |
2# |
40……140 |
18 |
4.0 |
* 2 1/2" |
2# |
110……340 |
15 |
|
* 3" |
2# |
180……470 |
18 |
|
* 4" |
2# |
350……920 |
20 |
|
* 3" |
3# |
115……220 |
20 |
|
* 4" |
3# |
210……590 |
20 |
|
* 5" |
3# |
380……1200 |
40 |
|
* 6" |
3# |
550……1800 |
80 |
|
Note:
1. "*" data is reference data
2. Flow adjustment range: refers to the adjustment range of the lower switching value, that is, the setting value adjustment range that causes the switch contact to switch when the flow decreases.
3, 4 #, 5 # targets can be used for larger diameter pipes.
◇ Attachments:
1 # ~ 5 # one target plate, 2 M3 × 8 screws, 2 Ф3 washers, 2 Ф3 spring washers.