Description
Product description:
WSSX-481, WSSX-301, WSSX-302, WSSX-303, WSSX-401, WSSX-403, WSSX-501, WSSX-502, WSSX-503, WSSX-311, WSSX-312, WSSX-313, WSSX-411, WSSX-412, WSSX-413, WSSX-511, WSSX-512, WSSX-513, WSSX-381, WSSX-382, WSSX-383, WSSX-481, WSSX-482, WSSX-483, WSSX-581, WSSX-582, WSSX-583, WSSX-351, WSSX-352, WSSX-353, WSSX-451, WSSX-452, WSSX-453, WSSX-551, WSSX-552, WSSX-553, WSSX-361, WSSX-362, WSSX-363, WSSX-461, WSSX-462, WSSX-463, WSSX-561, WSSX-562, WSSX-563, WSSX-371, WSSX-372, WSSX-373, WSSX-471, WSSX-472, WSSX-473, WSSX-571, WSSX-572, WSSX-573 electric contact bimetal thermometer drives the contact change when the temperature changes. When it contacts or disconnects with the upper and lower limit contacts, the relay in the circuit acts to automatically control and alarm.
Application:
The electric contact bimetal thermometer is applied to the production site to automatically control and alarm the temperature. Direct measurement of body and steam in the range of -80 to 500 °C in various production processes
And gas medium temperature.
Features of the electric contact bimetal thermometer:
· Display temperature on site, intuitive and convenient;
· With automatic power off and alarm function;
· Safe and reliable, long service life;
· A variety of structural forms to meet different requirements.
Technical parameter:
· Product implementation standards: JB/T8803-1998 GB3836-83
· Dial nominal diameter: 100
· Accuracy level: (1.0), 1.5
· Thermal response time: ≤40S
· Protection level: IP55
· Normal working atmospheric conditions: temperature -25 ~ +55 ° C, relative humidity ≤ 85%
· Setpoint error: The setpoint error should not exceed 1.5 times the basic error limit.
· Switching difference: The switching difference should not exceed 1.5 times the basic error limit.
· Switching repeatability: The switching repeatability limit range is not more than 1/2 of the absolute value of the basic error limit.
Precautions:
1, the scope of use: -50-50 ° C; -20-80 ° C; 0-50 ° C; 0-100 ° C; 0-120 ° C; 0-150 ° C ° C; 0-200 ° C;; 0-300 ° C; -400; 0-500 °C special can be customized.
2, the installation of screw teeth (active teeth and fixed teeth can be customized) 27 × 2mm; 3 / 4; 1/2; 1/43: applicable ambient temperature -40 ~ +85 ° C, relative humidity 5 ~ 100%. 4: Dial diameter: 100mm, universal mounting type. IV. Use and maintenance
3. In the storage, use and installation of the bimetal thermometer, avoid collision with the support tube, do not bend the support tube and use the case wrench.
4. All kinds of bimetal thermometers should not be used to measure the temperature of the medium in the open container. The live contact thermometer is not allowed to work under strong vibration, so as not to affect the reliability of the joint.
5. When the pressure is greater than 1.5MPa, the JX series protection tube should be selected.
WSSX-481, WSSX-301, WSSX-302, WSSX-303, WSSX-401, WSSX-403, WSSX-501, WSSX-502, WSSX-503, WSSX-311, WSSX-312, WSSX-313, WSSX-411, WSSX-412, WSSX-413, WSSX-511, WSSX-512, WSSX-513, WSSX-381, WSSX-382, WSSX-383, WSSX-481, WSSX-482, WSSX-483, WSSX-581, WSSX-582, WSSX-583, WSSX-351, WSSX-352, WSSX-353, WSSX-451, WSSX-452, WSSX-453, WSSX-551, WSSX-552, WSSX-553, WSSX-361, WSSX-362, WSSX-363, WSSX-461, WSSX-462, WSSX-463, WSSX-561, WSSX-562, WSSX-563, WSSX-371, WSSX-372, WSSX-373, WSSX-471, WSSX-472, WSSX-473, WSSX-571, WSSX-572, WSSX-573 electric contact bimetal thermometer drives the contact change when the temperature changes. When it contacts or disconnects with the upper and lower limit contacts, the relay in the circuit acts to automatically control and alarm.
Application:
The electric contact bimetal thermometer is applied to the production site to automatically control and alarm the temperature. Direct measurement of body and steam in the range of -80 to 500 °C in various production processes
And gas medium temperature.
Features of the electric contact bimetal thermometer:
· Display temperature on site, intuitive and convenient;
· With automatic power off and alarm function;
· Safe and reliable, long service life;
· A variety of structural forms to meet different requirements.
Technical parameter:
· Product implementation standards: JB/T8803-1998 GB3836-83
· Dial nominal diameter: 100
· Accuracy level: (1.0), 1.5
· Thermal response time: ≤40S
· Protection level: IP55
· Normal working atmospheric conditions: temperature -25 ~ +55 ° C, relative humidity ≤ 85%
· Setpoint error: The setpoint error should not exceed 1.5 times the basic error limit.
· Switching difference: The switching difference should not exceed 1.5 times the basic error limit.
· Switching repeatability: The switching repeatability limit range is not more than 1/2 of the absolute value of the basic error limit.
Precautions:
1, the scope of use: -50-50 ° C; -20-80 ° C; 0-50 ° C; 0-100 ° C; 0-120 ° C; 0-150 ° C ° C; 0-200 ° C;; 0-300 ° C; -400; 0-500 °C special can be customized.
2, the installation of screw teeth (active teeth and fixed teeth can be customized) 27 × 2mm; 3 / 4; 1/2; 1/43: applicable ambient temperature -40 ~ +85 ° C, relative humidity 5 ~ 100%. 4: Dial diameter: 100mm, universal mounting type. IV. Use and maintenance
3. In the storage, use and installation of the bimetal thermometer, avoid collision with the support tube, do not bend the support tube and use the case wrench.
4. All kinds of bimetal thermometers should not be used to measure the temperature of the medium in the open container. The live contact thermometer is not allowed to work under strong vibration, so as not to affect the reliability of the joint.
5. When the pressure is greater than 1.5MPa, the JX series protection tube should be selected.